Journal of Chromatography & Separation Techniques

Journal of Chromatography & Separation Techniques
Open Access

ISSN: 2157-7064

+44 1300 500008

Research Article - (2012) Volume 3, Issue 2

Organic Solvent-Free and Simple Method for Determining Cyromazine and its Metabolite, Melamine, in Cow's Milk

Naoto Furusawa*
Graduate School of Human Life Science, Osaka City University, Osaka 558-8585, Japan
*Corresponding Author: Naoto Furusawa, Graduate School of Human Life Science, Osaka City University, Osaka 558-8585, Japan, Tel: 81-6605-2864 Email:

Abstract

This paper described an organic solvent-free, rapid, simple, and space-saving method of sample preparation followed by HPLC coupled photo-diode array (PDA) detector for simultaneous quantification of cyromazine (CYR) and its decycropropylated metabolite, melamine (MEL), in milk. The HPLC-PDA was performed on an InertsilR HILIC column with an isocratic aqueous mobile phase. Analytes were extracted from the sample using water, and purified by MonoSpinR-C18, a centrifugal monolithic silica spin mini-columns, and quantified within 20 min. The method, performed under 100% aqueous conditions, obtained average recoveries for CYR and MEL in the range of 93.2 . 99.1% with relative standard deviations . 2.8%. The quantitation limits were 8.5 ng/mL for CYR and 10 ng/mL for MEL, respectively. No organic solvents were used at any stage of the analysis.

Keywords: Cyromazine; Melamine; HPLC-PDA; Milk; Organic solvent-free

Introduction

Cyromazine (CYR) is a triazine insect growth regulator used as an insecticide. In veterinary medicine, CYR is used as an ectoparasiticide and is added to animal feed to prevent fly from the manure, so as to improve the hygiene control of animal housing environments. CYR can be decycropropylated to melamine (MEL) (Figure 1) in plants and food-producing animals. The biotransformed MEL has been isolated from laying hen, goat, sheep, cow, and their products [1].

chromatography-separation-techniques-Molecular-structures

Figure 1: Molecular structures of cyromazine and its decycropropylated metabolite (melamine).

The 2008 Chinese milk scandal broke as infants consumed formula containing MEL were falling sick with urinary calculus and kidney damage [2] and the melamine adulteration of a variety of food products has instantly become a global problem. MEL, a nitrogen-rich organic chemical, is added to milk to boost the protein levels, making them appear higher than they actually are. Chronic exposure may lead to reproductive damage, or bladder or kidney stones, which can lead to bladder cancer [3-7].

On October, 2008, FDA issued its Interim Safety and Risk Assessment of MEL in Food for Humans in consideration of the potential public health concerns from foods.

In applying an additional 10-fold safety factor and using the TDI (Tolerable Daily Intake) of 0.63 mg/kg b.w./day, the safety/risk assessment concluded that a maximum tolerance levels of MEL below 2.5 ppm in foods other than infant formula do not raise public health concerns [8].

In response the global MEL problem, the United Nations food standards body, the Codex Alimentarius Commission, announced formal international limits for melamine allowed in food and animal feed during its meeting on July, 2010. The maximum amount of MEL allowed in foods and animal feed is 2.5 mg/kg, equal to the FDA limit. The international maximum levels help governments differentiate between low levels of unavoidable melamine occurrence that do not cause health problems, and deliberate adulteration—thereby protecting public health without unnecessary impediments to international trades [9].

Milk contains a good balance of protein, fat and carbohydrate, is an indispensable food because it is inexpensive and readily available. It becomes a raw material of every processed food.

To ensure that milk for human consumption is residue-free of CYR, the Codex has set a maximum residue limit (MRL) for CYR in milk at 10 ng/mL [10]. Strict and rapid monitoring the presences of CYR and MEL in milk is, therefore, an important means of guaranteeing the international food safety.

In response to the recent expansion in the internal food trade, the development of international harmonized methods to determine chemical residues in foods is essential to guarantee equitable international trade in these foods and protect health for consumers. Whether in industrial nations or developing countries, an internal harmonized method for residue monitoring in foods is urgentlyneeded. The optimal harmonized method for the routine monitoring chemicals such as melamine in foods must be simple, small scale, economical in time and cost, and must cause no harm to the environment and humans.

The Food Safety and Inspection Service (FSIS) of the United States Department of Agriculture (USDA) have been provided a test method based on high-performance liquid chromatography (HPLC) for analyzing CYR and MEL in animal tissues in its Chemistry Laboratory Guidebook which contains test methods used by FSIS Laboratories to support the Agency’s inspection program, ensuring that meat, poultry, and egg products are safe, wholesome and accurately labeled [11]. Previous techniques based on high-performance liquid chromatography (HPLC) for simultaneous determination of CYR and MEL in animal-derived foods [12-16] has crucial drawbacks: 1) all of methods consume organic solvents in the instrumental analyses as well as for extraction and de-proteinization in sample preparation. The risk associated with these solvents extends beyond direct implications to human health by affecting the ecosystem in which we all reside. Furthermore, the disposal of waste organic solvents through incineration has steadily increasing over the past decade and costs large amounts of money. Thus, eliminating the use of organic solvents and reagents is an important goal in terms of protecting the environment, human health, and the economy [17,18]. 2) most of the recent methods are based on LC-MS/MS. The facility is available are limited to part of industrial nations because these are hugely expensive, and the methodologies use complex and specific. These are unavailable in a lot of laboratories for routine analysis, particularly in developing countries. No optimal method that satisfies the aforementioned requirements has yet been identified.

This article describes an ultra safe, idiot proof, and inexpensive method to strictly monitor CYR and MEL residues in milk using a 100% aqueous solution in sample preparation and HPLC separation without organic solvent consumption.

Experimental

Reagents

Standards of cyromazine (CYR) and melamine (MEL) and other chemicals were purchased from Wako Pure Chem. Ltd. (Osaka, Japan). Distilled water was of HPLC grade. 0.5 moL/L 1-octanesulfonic acid sodium salt solution (low UV type) was of ion-pair chromatography grade. These standards and chemicals were greater than 99% purity.

Apparatus

The following apparatuses were used in the sample preparation: handheld ultrasonic-homogenizer (model HOM-100, 2 mm ID probe, Iwaki Glass Co., Ltd., Funabashi, Japan); micro-centrifuge (BiofugeR fresco, Kendo Lab. Products, Hanau, Germany); two types of MonoSpinR as centrifugal monolithic silica spin mini-columns (sample throughput volume . 300 µL), MonoSpin-C18 (octadecyl and nonpolar functional group) and MonoSpin-SCX (bonded propyl benzene sulfone acid combining both strong cation and non-polarity) (GL Sciences, Inc., Tokyo, Japan). The following types of non-polar sorbent columns (5 µm dp, 150~4.6 mm) for HPLC were used: Wakosil 5TMS (C1) (Wako); MightysilR RP-4GP (C4) (Kanto Chemical Co., Inc., Tokyo, Japan); MightysilR RP-18 GP Aqua (C18) (Kanto); InertsilR ODS-4 (C18) (GL Science); InertsilR HILIC (alkyl diol) (GL Science) (Table 1).

The HPLC system, used for method development, included a model PU-980 pump and DG-980-50-degasser (Jasco Corp., Tokyo, Japan) equipped with a model CO-810 column oven (Thosoh Corp., Tokyo, Japan), as well as a model SPD-M10AVP photodiode-array (PDA) detector (Shimadzu Scientific Instruments, Kyoto, Japan). Table 1 lists the particle physical specifications.

HPLC operating conditions

The analytical column was an Inertsil® HILIC (150 × 4.6 mm, 5 μm dp) column using a 0.05 moL/L1-octanesulfonic acid mobile phase at a flow rate of 1.0 mL/min at 40°C. PDA detector was operated at 190-300 nm: the monitoring wavelength was adjusted to 206 nm which represents an average maximum for the analytes. The injection volume was 20 μL.

Preparation of stock standards and working mixed solutions

Stock standard solutions of CYR and MEL were prepared by dissolving each of CYR and MEL in water to a concentration of 10,000 ng/mL. Working mixed standard solutions of these two compounds were prepared by suitably diluting the stock solutions with water. These solutions were kept in a refrigerator (5°C).

Preparation of calibration standards and quality control samples

For method validation studies, calibration standards and quality control samples (QCs), terms defined in the FDA guideline [19], were prepared by spiking appropriate aliquots of the mixed standard solution in blank milk samples. Calibration standards were used to construct calibration curves from which the concentrations of analytes in unknown monitoring samples are determined practically. QCs used to evaluate the performance of the proposed method. In this study, the standards were prepared in the range of 20 – 1,000 ng/mL for CYR and 20 – 3,000 ng/mL, respectively. Three QC levels (QC1 = 30 ng/mL for CYR and 50 ng for MEL; QC2 = 100 ng/mL for both analytes; QC3 = 500 ng/mL for CYR and 250 ng/mL for MEL) were prepared.

Sample preparation

An accurate 0.1 mL sample was taken into a micro-centrifuge tube and homogenized with 0.6 mL of water with a handheld ultrasonichomogenizer for 30 s. After being homogenized, the capped tube was centrifuged at 10,000 g for 5 min. A 0.1 mL of supernatant liquid was poured to a MonoSpin-C18 and centrifuged at 3,500 g for 1 min. The eluate was injected into the HPLC system.

Method validation

The performance of the developed method was validated in terms of some parameters from the international guidelines for bio-analytical procedure [19-24]. The quality parameters established were standard solution stability, linearity, accuracy, precision, sensitivity, specificity, selectivity, robustness, system suitability.

Results And Discussion

Sample preparation

The ultrasonic-homogenization enabled the satisfactory extraction of CYR and MEL from a milk sample with a 100% water. The author used two types of centrifugal monolithic silica spin mini-columns, MonoSpins (MonoSpin-C18 and-SCX), for the further cleanup technique. The spin mini-column is a monolithic SPE column excellent for the small volume sample with easy and quick operation by centrifuge [25]. A 100% water was used as the eluent and the recoveries of CYR and MEL from these mini-columns were compared. Since the recoveries of the target compounds from the column vary with centrifugal acceleration (rotary speed), this study was also investigated an optimal acceleration (. 1,000 g) to recovery CYR and MEL from the spin minicolumns. A 100 µL portion of a mixed standard solution containing 0.5 µg of each compound was applied to the spin mini-column. The centrifugal time was standardized at 1 min. MonoSpin-C18 gave satisfactory recoveries (. 96%) and repeatabilities (RSD . 2%, n=3) for CYR and MEL when the centrifugal acceleration was 3,500 g for 1 min. The MonoSpin-C18 was therefore used a centrifugal monolithic silica spin mini-column. The present procedure can realize small-scale extractions and easy purifications of CYR and MEL in a short time while completely eliminating the consumption of organic solvents. The procedure resulted in high recoveries and repeatabilities.

Optimum HPLC conditions

In order to achieve the separation with a 100% aqueous mobile phase, this study tested five types of non-polar sorbent columns. Table 1 lists the physical and chemical specifications. The author used 0.05 moL/L 1-octanesulfonic acid as the isocratic aqueous mobile phase and examined column temperatures ≥ 25°C, flow rates ≥ 0.5 mL/min, and HPLC retention times ≤ 15 min. Because the HPLC separations were performed serially, the time per run was critical for routine residue monitoring. The short run time not only increased sample throughout for analysis but also affected the method-development time. The seven columns were compared with regard to the separation among CYR, MEL, and their interfering peaks obtained upon injection of equal amounts. The chromatographic separations within the conditions ranges examined are also presented in Table 1.

Column Pore diameter (nm) Pore volume (mL/g) Surface area (m2/g) Carbon load (%) HPLC separation
Symbol Silica (type) Trade name
A C1 Wakosil 5TMS 12 1.0 300 4 Not Separated (NS)c
B C4 Mightysil RP-4 GP 12.5 1.1 350 4 NS
C C18 Mightysil RP-18 GP Aqua 13.5 0.9 270 15 NS
D C18 Inertsil ODS-4 10 1.05 450 11 NS
E Alkyl diol Inertsil HILIC (alkyl diol) 10 1.05 450 20 Completely separated

a150×4.6 mm; dp= 5 μm: data supplied from manufactures.
bMobile phase of water; column temperatures ≥ 25°C; flow-rates ≥ 0.5 mL/min; HPLC retention times ≤ 15 min.
c Not separated: between MEL and the interfering milk extract.

Table 1: Physical/chemical specifications of the reversed-phase columnsa used and chromatographic CYR and MEL separations obtained under the HPLC conditions examinedb

Columns A-D had difficulty separating MEL and the interfering milk extract throughout the examined condition ranges. An ideal chromatogram with complete separations of CYR, MEL, and interfering peaks, and their short retention times was obtained by a Column E and a 0.05 moL/L 1-octanesulfonic acid mobile phase with a column temperature of 40°C and a flow rate of 1.0 mL/min. The HPLC system achieved optimal separation < 6.5 min without the need for a gradient system to improve the separation. The ion-pair action of 1-octanesulfonic acid mobile phase used here was necessary to obtain the findings described.

Figure 2 displays that the resulting chromatograms were free of interfering compounds for quantitation and identification of CYR and MEL by HPLC, with PDA detector set at 206 nm (giving an average maximum for CYR and MEL). This figure demonstrates that the present method can provide the quantitation and identification of CYR and MEL.

chromatography-separation-techniques-lower-profile

Figure 2: Chromatograms obtained from the HPLC system for a blank milk sample (upper profile) and a milk sample spiked with CYR (500 ng/mL) and MEL (250 ng/mL) (lower profile). The PDA detector was set at 206 nm. Peaks, 1= MEL (retention time, Rt= 3.08 min); 2= CYR (Rt= 6.23 min).

Method validation

Main quality parameters: Table 2 summarizes the values obtained for the main parameters. The stability of a working mixed standard solution (1,000 ng/mL of each compound) was evaluated at room temperature, 25°C, for 24 h and 5°C for 10 days, respectively. After completion of the storage time, the stability was tested by comparing the HPLC response with that of freshly prepared solution. The resulting stabilities were well within the international acceptance criteria [22]. The correlation coefficients for CYR in the range of 20-1,000 ng/mL and MEL in the range of 20-3,000 ng/mL were 0.991 and 0.994, respectively. The resulting line showed a significant linearity for individual compound (P <0.01). The accuracy and precision are well within the acceptance criteria [19-21,23]. The QL for CYR (9 ng/ mL) was lower than the MRL of 10 ng/mL [10]. The other validation findings are as follows:

Parameter CYR MEL
Standard stabilitya:
At 25°C for 24 h
At 5°C for 10 days
101.0 (0.6)
98.6 (0.8)
99.3 (0.9)
100.6 (1.0)
Linearity (rb) 0.991 0.994
Accuracyc 93.2 – 97.8 94.5 – 99.1
Precisiond ≤ 2.8 ≤ 2.4
Sensitivity (QLe) 8.5 10

a The chromatographic peak area (%) after completion of the store time: data are expressed as averages (n=5, for each compound); relative standard deviation (RSD) in parentheses (%).
b r is the correlation coefficient (P< 0.01): mean of three determinations using spiked milk samples for calibration curves: ranges of concentrations were 20–1,000 ng/mL for CYR and 20 – 3,000 ng/mL for MEL, respectively.
c Average recoveries (%) from six replicates at three QC levels (QC1 = 30 ng/mL for CYR and 50 ng for MEL; QC2= 100 ng/mL for both analytes; QC3 = 500 ng/ mL for CYR and 250 ng/mL for MEL).
d Values are RSDs (%, n=6 of each level).
e Quantitation limit (ng/mL), QL as the concentration of analyte giving a signalto- noise ratio > 10.

Table 2: The main method validation data.

Specificity and selectivity: The application of the proposed procedure to 10 blank milk samples from different species (Holstein- Friesian and Jersey) demonstrated that no interference peak was presented around the retention times for CYR and MEL in any of the sample examined.

The present HPLC-PDA system easily confirmed the peak identity of target compound. CYR and MEL were identified in a milk sample by their retention times and absorption spectra. The CYR and MEL spectra obtained from the milk sample were practically identical to those of the standards. Because of the complete separations and the high absorbance of CYR and MEL, PDA detection at trace levels is fully available. It is, therefore, instructive to demonstrate purification effectiveness of the sample preparation. The system did not require the use of MS, which is very expensive and is not available in a lot of laboratories for routine analysis, particularly in developing countries.

Robustness: Some HPLC parameters were performed using a spiked (100 ng/mL of each compound) milk sample obtained under the established procedure.

Changes of ±5% units of the flow rate (1.0 mL/min) and the column temperature (40°C) were determined. The effect on the peak areas and the validations in the retention times were evaluated. Changes of ± 5% of the flow rate and the column temperature had no effect on the peak areas, whereas the variations in the retention times were obtained with the flow rate and the column temperature. Normal retention times for CYR and MEL were 6.23 and 3.08 min, respectively. At +5% the flow rate, the two retention times were decreased, ranging between 1.6 and 5.7% and at -5%, the times were increased ranging between 5.5 and 8.0%. By changing the column temperature by +5%, decreasing retention times obtained were 1.9-7.5%, however, no significant variations were observed with -5%. During these studies, all the target compounds were separated.

System suitability: The system-suitability evaluation is an essential parameter of HPLC determination, and it ascertains the strictness of the system used. The suitability was evaluated as the relative standard deviations of peak areas and retention times calculated for 20 replicate injections of a spiked milk sample (100 ng/mL of each compound). The values for CYR and MEL were estimated to be <0.5% for peak areas and <0.8% for retention times, respectively.

Cost and time performance: The total time and budget required for the analysis of a single sample was < 20 min and approximately US $6.1 as of March 5, 2012, respectively. For sequential analyses, a batch of 24 samples could be analyzed in 4 h. These findings became term required for an international harmonized residue analysis. The organic solvent-free and short analytical time not only increased the sample throughput for analysis but also positively affected the cost and environmental/human impacts.

Application to residue monitoring in commercial samples

Milk was purchased from a number of convenience stores in Osaka, Japan, used as real milk samples and analyzed using the proposed method. No samples contained detectable concentrations of CYR and MEL. The resulting chromatograms were free from interference.

Conclusion

An organic solvent-free method does not use organic solvents for simultaneous determination of CYR and MEL in milk has been successfully developed and validated. The present procedure provided an easy-to-use, rapid, space-saving, and non-use of organic solvents and resulted in high recovery and repeatability with considerable saving of analysis time/cost. The procedure may be proposed as an international harmonized analytical method for the routine monitoring of CYR and MEL in milk.

References

  1. FAO, Pesticide Management, JMPR evaluation, List of Pesticides evaluated by JMPR and JMPS, Cyromazine. JMPR No. (169): 2009 (R) Evaluation.
  2. Hau AK, Kwan TH, Li PK (2009) Melamine toxicity and the kidney. J Am Soc Nephrol 20: 245-250.
  3. WHO – Some Chemicals that care Tumors of the Kidney or Urinary Bladder in Rodents and Some Other Substances.
  4. Heck HD, Tyl RW (1985) The induction of bladder stones by terephthalic acid, dimethyl terephthalate, and melamine (2,4,6-triamino-s-triazine) and its relevance to risk assessment. Regul Toxicol Pharmacol 5: 294-313.
  5. WHO, Media centre, International experts limit melamine levels in food.
  6. Tittlemier S, Health Canada, Background Paper on Methods for the Analysis of Melamine and Related Compounds in Foods and Animal Feeds, Ottawa, Ontario, Canada, 1-4 December 2008.
  7. Yu H, Tao Y, Chen D, Wang Y, Liu Z, et al. (2010) Development of a high performance liquid chromatography method and a liquid chromatography-tandem mass spectrometry method with pressurized liquid extraction for simultaneous quantification and confirmation of cyromazine, melamine and its metabolites in foods of animal origin. Anal Chim Acta 682: 48-58.
  8. Wang S, Li D, Hua Z, Zhao M (2011) Molecularly imprinted monolith coupled on-line with high performance liquid chromatography for simultaneous quantitative determination of cyromazine and melamine. Analyst 136: 3672-3679.
  9. Sun HW, Wang LX, Liu N, Qiao FX, Liang SX (2009) SPE then RP-LC for simultaneous analysis of cyromazine and its metabolite melamine in liquid milk and egg. Chromatographia 70: 1685-1689.
  10. Wei R, Wang R, Zeng Q, Chen M, Lui T (2009) High-performance liquid chromatographic method for the determination of cyromazine and melamine residues in milk and pork. J Chromatogr Sci 47: 581-584.
  11. Anastas PT, Warner JC (1998) Green Chemistry: Theory and Practice, Anastas PT and Warner JC, Eds. Oxford University Press, Oxford, United Kingdom.
  12. Yoshimura T, Nishinomiya T, Homda Y, Murabayashi M (2001) Green Chemistry – Aim for the Zero Emission-Chemicals, Sankyo Publishing Co. Ltd. Press, Tokyo, Japan.
  13. FDA/CDER/CVM, Guidelines for Industry – Bioanalytical Method Validation, 2001.
  14. Huber, L (1998) (ed), Validation and Quantification in Analytical Laboratories, Interpharm Press, East England, CO, USA.
  15. Codex alimentarius commission, ALINORM 01/23, Codex Committee on Methods of Analysis and Sampling, Joint FAO/WHO Food Standards Programme, the 23nd Seccion of the Codex Committee on Method of Analysis and Sampling.
  16. GL Sciences, Monolithic SPE Column for the Purification and Enrichment of Small Amount Sample, MonoSpin® Series.
Citation: Furusawa N (2012) Organic Solvent-Free and Simple Method for Determining Cyromazine and its Metabolite, Melamine, in Cow’s Milk. J Chromatograph Separat Techniq 3:121.

Copyright: © 2012 Furusawa N. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.