Anesthesia & Clinical Research

Anesthesia & Clinical Research
Open Access

ISSN: 2155-6148

Research Article - (2019) Volume 10, Issue 11

Value of Integrated Lung and Diaphragm Ultrasonography in Predicting Extubation Outcomes from Mechanical Ventilation in Patients with Critical Illness

1Department of Anesthesia and Intensive Care, Aswan University, Aswan, Egypt
2Department of Chest Diseases and Tuberculosis, Aswan University, Aswan, Egypt

Abstract

Background: A primary priority for all intensivists is identifying strategies to reduce the duration of Mechanical Ventilation (MV) and deciding the ideal time for extubation.

Aim: To evaluate the role of the diaphragm and lung ultrasonography principally (DE, DTF, and LUS scores) in the prediction of extubation outcomes from MV.

Patients and methods: This prospective observational study included sixty-eight adult patients who required invasive MV for as a minimum of 24 hours and successfully passed a spontaneous breathing trial (SBT) were enrolled in our study. At the end of a successful SBT, we assessed by ultrasound DE, DTF and lung parenchyma.

Results: 53 patients (78%) successfully extubated while, 15 patients (22%) experienced failed extubation. DTF% with cutoff value ≥ 30% had the highest sensitivity (100%), negative predictive value (100%) and the highest accuracy (89.24%). On combining DTF% ≥ 30% and LUS ≤ 12, specificity and the diagnostic accuracy raised to (100% and 96% respectively) with highly precise AUC (0.97).

Conclusion: The integration of DTF % ≥ 30% of the right hemi-diaphragm with LUS ≤ 12 improved the expectation of successful extubation in comparison with DTF % alone.

Keywords: Diaphragm; Lung; Ultrasonography; Extubation; Mechanical ventilation

Introduction

Nowadays Mechanical Ventilation (MV) is considered a fundamental life support strategy that is used in many patients with critical illness and has proven to decrease mortality rates [1]. Once mechanical ventilation initiated; planning for weaning should starts. Timing of weaning is crucial to avoid many complications [2]. Liberation from mechanical ventilation is considered a major issue in critical care practice.

Traditionally; decision to start weaning process is taken after improvement of patient's clinical condition, arterial blood gas parameters and largely depends on clinical experience [3]. However, approximately 14% to 32% of the patients meeting these criteria were undergoing extubation failure (EF). For identifying the right time to extubate patients from invasive mechanical ventilation, several ventilatory indices have been established; however, none of them fulfilled the criteria necessary to deliver properly precise success rates [4].

In recent times, lung and diaphragm ultrasonography approaches have been presented to evaluate the patterns of the pulmonary airway and the diaphragmatic function. Moreover, lung ultrasonography can be used as an effective measure in the evaluation of lung aeration which is useful during the weaning procedure as it reflect the aeration loss and consequently predict the respiratory distress in the post extubation period, a validated score termed the lung ultrasound score (LUS) can be used to evaluate the loss of lung aeration [5].

Numerous data measured through diaphragmatic ultrasonography have been recommended for the same purpose [6-7], which involve measurement of diaphragmatic muscle movement during inspiration or excursion during the respiratory cycle (DE) [8], and diaphragmatic muscle thickening or diaphragmatic thickening fraction (DTF). The primary aim of the present study was to evaluate the role of the lung and diaphragm ultrasound in particular the DE, DTF and LUS scores to predict extubation outcomes. The secondary outcome was to compare these ultrasonography data with the other traditional weaning criteria.

Patients and Methods

This prospective observational study includes a total of 85 patients required invasive mechanical ventilation for a minimum of 24 hours and achieved the weaning criteria. Approval of the ethical committee and a written informed consent was given by surrogate decision maker.

This study was conducted at the Surgical ICU in Aswan University Hospital, during the period from May 2017 to December 2018.

Included patients underwent full clinical examination, Chest radiography, routine laboratory investigations (whenever needed) and arterial blood gases (ABG) on daily basis; also before and after start of SBT.

Weaning procedure

All patients who meet the following weaning criteria undergo SBT, which include, improvement of disease acute phase which necessitated mechanical ventilation, stable neurological status, no hemodynamic instability (heart rate ≤ 120/min, systolic blood pressure higher than 90 mmHg and lower than 160 mmHg) in the absence of any vasoactive support therapy, PaO2>60 mm Hg or SaO2 ≥ 90% or more with FiO2 ≤ 0.4, spontaneous respiratory rate (RR)<35 breath/min, exhaled tidal volume (VT)>5 ml/kg of ideal body weight, afebrile and there were no significant abnormalities in the electrolyte levels.

Patients who were hemodynamic unstable (heart rate>140, systolic blood pressure>180 or<90 mmHg), those with severe intracranial disease, with tracheostomy, severe ICU acquired neuromyopathy, with primary unilateral/bilateral absence of diaphragmatic mobility, and who had previously failed SBT, were excluded from the study.

Variables monitored during SBT

Patients underwent a SBT for at least two hours by putting the patient on spontaneous mode of weaning with low-level pressure support (8 cm H2O) and PEEP level (≤ 5 cm H2O) using GE ventilator (Carescape R860, USA). Dyspnea, fatigue, anxiety and distress were subjectively assessed.

Vital signs were monitored and recorded. Ventilatory data were recorded including exhaled tidal volume, breathing rate, minute ventilation, maximal inspiratory pressure (Pimax) and rapid shallow breathing index (RSBI). Patients, who passed the SBT without worsening, were extubated and received oxygen therapy with Venturi mask and then monitored for 48 hours after extubation. A successful extubation was defined as preservation of spontaneous breathing without any ventilatory support for ≥ 48 hours following extubation [9-10].

Ultrasound examination

At the end of a successful SBT, lung and diaphragm ultrasound examination were done. All the included cases in our study were assessed in a semi-recumbent position. Ultrasound was accomplished using GE ULTRASOUND (LOGIQ C5 Premium, GE MEDICAL SYSTEMS (CHINA) CO, LTD).

Diaphragm ultrasonography

Evaluation of diaphragmatic excursion: we measured the amplitude of diaphragmatic inspiratory excursion as the highest point of maximal inspiration in the motion mode (M-mode) with the use of 3.5-5 MHz curvilinear probe, which was positioned immediately underneath the right subcostal margin in the mid-clavicular line and was moved upward till better visualization of the posterior portion of the right hemi-diaphragm [11,12] as shown in Figure 1.

anesthesia-clinical-research-Diaphragm

Figure 1: Diaphragm excursion is evaluated in the M-mode with the use of 3.5-5 MHz curvilinear probe.

Evaluation of diaphragmatic thickness and thickness fraction

The diaphragmatic thickness was evaluated with the use of a 7-10 MHz linear probe in B-mode as shown in Figure 2.

anesthesia-clinical-research-Diaphragmatic

Figure 2: Diaphragmatic thickness is evaluated in the B-mode with the use of 7-10 MHz linear probe.

The right hemi-diaphragm was seen at the region of apposition, on the midaxillary line between the 8th and 10th intercostal spaces, where we viewed the diaphragm as three layered structure (two parallel echogenic lines demonstrating the diaphragmatic pleura and the peritoneum with central hypoechoic space representing the diaphragmatic muscle) [13].

Measurement of the degree of diaphragm thickening had been planned to be more accurate than the evaluation of thickness alone, the diaphragmatic thickness fraction (DTF) was considered as=[(Thickness at the end inspiration-thickness at the end expiration)/ Thickness at the end expiration] [14].

B-Lung ultrasound: For the evaluation of Lung parenchyma, each lung was divided into 3 zones underwent evaluation anteriorly and posteriorly with the use of B-mode to check the degree of lung aeration with a total of 12 zones to be assessed [15], as shown in Table 1.

Points for each lung zone (12 zones) Status of lung aeration Lung ultrasound pattern
0 point Normal aeration Horizontal A-line (no exceed three B-line)
1 point Average loss of aeration numerous B-line with regular or irregular spacement
2 point Marked aeration loss Multiple coalescent B-lines
3 point Complete aeration loss Lung consolidation
Total score From 0 to 36  

Table 1: Illustrates the lung ultrasound score for detection of the degree of lung aeration.

Statistical analysis

SPSS (Statistical Package for Social Science) software program version 19.0 (SPSS Inc., Chicago, IL) was used for data recording and handling. Data was presented as (mean ± SD) for continuous variables. Student’s t tests were used for the comparison of continuous variables and chi-square tests were used to compare numerical variables.

Non-parametric tests were used for abnormal distributed data in the current study. To assess the accuracy of each weaning index, Receiver operator characteristic curves (ROC) were used and the nonparametric method of Delong was used to calculate the area under the ROC curves (AUC) for each weaning index. P value ≤ 0.05 considered significant.

Results

During the study period, we evaluated 85 patients (50 males and 35 females) eligible for weaning. Ten subjects were excluded from the study, three of which had hemodynamic instability, 4 cases had previously failed SBT and 3 had a decreased level of consciousness. Among the 75 patients underwent SBT, 7 patients failed SBT and were omitted from data analysis. Sixty-eight patients were successfully passed SBT then extubated and monitored for 48 hours to evaluate extubation outcome.

Patients were classified according to the fate of extubation into a successful extubation group (53 patients) (78%) and failed extubation group (15 patients) (22%), who required re-intubation within 48 hours post-extubation due to respiratory distress or hypoventilation with respiratory acidosis as shown in Figure 3.

anesthesia-clinical-research-flow-chart

Figure 3: The flow chart of the study.

With the exception of the length of mechanical ventilation, all the demographic and clinical data did not differ considerably between the successfully extubated and failed groups (Table 2).

Demographic variable Successful extubation group (n=53) Failed extubation group (n=15) P Value
Age Mean ± SD 51.3 ± 16.5 54.5 ± 15.6 0.512
Gender Male no (%) 38 (71.7%) 8 (53.3%) 0.218
Female no (%) 15 (28.3%) 7 (46.7%)
Duration of MV (days) Mean ± SD 2.8 ± 0.76 5.8 ± 1.8 0.001*
Diagnosis on admission to ICU Polytrauma (%) 15 (28.3%) 4 (26.7%) 0.158
Sepsis (%) 15 (28.3%) 5 (33.3%)
Postpartum hemorrhage (%) 2 (3.7%) 1 (6.7%)
Acute pancreatitis (%) 3 (5.7%) 1 (6.7%)
Postoperative complications (%) 15 (28.3%) 2 (13.3%)
Pregnancy induced hypertension or eclampsia (%) 3 (5.7%) 2 (13.3%)

Table 2: Demographic and clinical data of the studied groups.

All the traditional weaning parameters including, (MAP, HR, PaO2/FiO2 ratio, RR, RSBI and PImax), were significantly different in the successful extubation group in comparison with the failed one (P<0.05) (Table 3). The diaphragmatic ultrasound parameters including DE and DTF% were considerably higher (P<0.001) in the successfully extubated group compared to the failed one, while LUS score was considerably lower (P<0.001) in the successfully extubated group in comparison with the failed one (Table 3).

  Successful extubation group (n=53) Failed extubation group (n=15) P Value
Mean ± SD Mean ± SD
MAP (mmHg) 96.2 ± 6.6 101.5 ± 9.04 0.015
HR (beat/min) 93.2 ± 11.9 120.7 ± 21.9 <0.001
PaO2/FiO2 ratio 211.8 ± 31.2 174.0 ± 24.7 <0.001
RR (breath/min) 24.8 ± 5.7 33.1 ± 6.2 0.001
RSBI (breath/min/l) 74.4 ± 14.9 100.5 ± 6.1 0.001
PImax -57.3 ± 18.2 -22 ± 4.5 0.001
DE (mm) 20.6 ± 7.3 8.5 ± 6.2 <0.001
DTF (%) 34.1 ± 1.9 23.4 ± 3.8 <0.001
LUS score 9.9 ± 5.3 18.9 ± 6.5 <0.001

Table 3: Comparison of the weaning parameters between the studied groups.

Diagnostic test performance of each index was used to predict extubation success (the traditional weaning parameters and ultrasonographic parameters) was shown in Table 4. DTF% with cutoff value ≥ 30% had the highest sensitivity (100%), negative predictive value (100%) and the highest accuracy (89.24%); while, its specificity and positive predictive value were (71.4% and 83.3% respectively). On combining DTF% ≥ 30% to LUS ≤ 12, specificity and positive predictive value raised to 100%, 96.0% accuracy and AUC was highly precise (0.97).

Diagnostic Validity Sensitivity Specificity PPV NPV Accuracy AUC
Traditional weaning parameters
RR ≤ 28 breath/min 78.2 60 76.1 66.3 65.8 0.636
RSBI ≤ 102 (breath/min/L) 80 65.3 77.8 69.7 70.4 0.719
PImax ≤ -25 (cm H2O) 80 70 78.3 71.6 72 0.727
PaO2/FiO2 ratio ≥ 188 79.3 80 93.3 52.2 79.4 0.832
Ultrasonography parameters
DE ≥ 11 (mm) 84.4 73.9 86.4 70.8 80.9 0.868
DTF ≥ 30 100 71.43 83.3 100 89.24 0.904
LUS score ≤ 12 80 78.3 87.8 66.7 79.4 0.889
DTF ≥ 30 and LUS score ≤ 12 95 100 100 92 96 0.971

Table 4: Diagnostic test performance for traditional and ultrasonography weaning parameters.

Discussion

Determining the ideal time for extubation in mechanically ventilated patients is an exciting topic as the traditional weaning predictor tools are not precise. Our study found that a right DTF of more than or equal to 30% had a better diagnostic accuracy for predicting extubation successfulness. In harmony with our results, the studies from Ferrari et al. [16], DiNino et al. [17], Dube et al. [18], and Blumhof et al. [19] confirmed that DTF above or equal 36, 30, 29, and 20%, respectively, were related to successful extubation. Moreover, from our analysis, the combination of right DTF of ≥ 30% and LUS score ≤ 12 improved the specificities and accuracy for expecting the success of the extubation procedure from mechanical ventilation compared to the use of DTF alone.

In our results, 15 patients representing (22%) of the study population experienced failed extubation and re-intubated within 48 hours. Similarly, previous studies revealed failure rate about 20, 26.7 and 23.3 percentages correspondingly [20-22]. However, Ferrari et al. described 63 failure rate percentage in patients ventilated through a tracheostomy tube [16].

The mean length of mechanical ventilation was considerably prolonged in our failed extubation group (5.8 ± 1.8 days) compared with the successful one (2.8 ± 0.76 days]. Similarly, Baess et al. (2016) established that the mean length of MV in the successful weaned group was (4 days) versus (7 days) in the failed one [22].

We observed highly substantial difference between patients who succeeded or failed extubation in comparing the traditional weaning predictors including (RSBI, PImax, RR, and PaO2/FiO2 ratio). Osman and Hashim [6] reported similar result regarding PImax, Nemer and Barbas [23] regarding RR, Farghaly and Hasan [24] regarding PaO2/FiO2 ratio, Ferrari et al. [16] and Saeed et al. [21] regarding RSBI, However, Farghaly and Hassan [24] reported that RSBI measured during SBT was insignificantly different between their successful and failed extubation groups.

The mean diaphragmatic excursion (DE), in our study was considerably higher in the successfully extubated group (19.7 ± 5.1 mm vs. 6.2 ± 3.1 mm) in comparison with the other group, the best cutoff value of diaphragmatic excursion that accurately prognosticate effective extubation in our study was minimally 11 mm with 84% sensitivity, however its specificity and negative predictive value were (73% and 70% respectively). This result was comparable with Farghally and Hasan [24] who reported that the best cutoff value of DE for prognostication of successful extubation was 10-11 mm.

In the present study, DTF percentage with cut off value ≥ 30 had 100% sensitivity but 71% specificity and 83% positive predictive value, similar result by Pirompanich and Romsaiyut in their study on 34 patients found that DTF percentage ≥ 26 had sensitivity of 0.96, specificity of 0.68, PPV of 0.89 and NPV of 0.86 [25], moreover, Osman and Hashim in their study on 68 patients demonstrated that DTF percentage more than 28 was the optimal cut off value that better predict successful weaning with 0.88 sensitivity and 1.00 specificity [6]. However, this result was in controversy to Ferrari et al. who described greater cut off value ≥ 36% with 0.82 sensitivity and 0.88 specificity [16], additionally, Farghaly and Hasan [24] reported that DTF percentage ≥ 34.2% was associated with the greatest sensitivity (0.90) in comparison with the other diaphragmatic parameters but with (0.64) specificity.

We found that the diagnostic test performance of LUS score to prognosticate extubation success with the best cut off value of ≤ 12 had sensitivity 80%, specificity 78%, NPV 66% and AUC 0.88 reflecting lower accuracy than previously mentioned weaning indices. In concordance with our results, Mayo et al. proposed that a LUS score<13 at the end of a SBT increased probability of achievement of extubation and a LUS score>17 was highly predictive of postextubation distress and increased the chance of failed extubation [26].

Finally, we found that the integration of DTF of more than or equal to 30% combined with LUS score of less than or equal to 12 improved the diagnostic accuracy for prediction of successful extubation compared to DTF alone (96% accuracy and the area under curve was 0.971).

Limitations

Our study is a single center study with small sample of selected patients. Moreover, the main limitation of our study that ultrasonography was operator dependable technique with several ultrasound limitations such as the existence of pneumothorax as well as the morbid obesity interfering with the maximum window for diaphragm imaging.

Conclusion

Ultrasonography measurement of DTF can provide appreciated data in the assessment of subjects during partial ventilatory support. Moreover, the integration of DTF ≥ 30% combined with LUS score ≤ 12 improved the likelihood of successful extubation in comparison with DTF alone.

Acknowledgments

The authors appreciate the ultimate help and support of the surgical intensive care unit residents and nurses in this research. No fund was paid by any institution.

References

  1. Ouellette DR, Patel S, Girard TD, Morris PE, Schmidt GA, et al. (2017) Liberation from mechanical ventilation in critically ill adults: An official American College of Chest Physicians/American Thoracic Society clinical practice guideline: Inspiratory pressure augmentation during spontaneous breathing trials, protocols minimizing sedation, and noninvasive ventilation immediately after extubation. Chest 151: 166-180.
  2. MacIntyre NR, Cook DJ, Ely EW Jr, Epstein SK, Fink JB, et al. (2001) Evidence-based guidelines for weaning and discontinuing ventilatory support. Chest 120: 375S-395S.
  3. Mador MJ (1992) Weaning parameters: Are they clinically useful? Chest 102: 1642-1643.
  4.  Savi A, Teixeira C, Silva JM, Borges LG, Pereira PA, et al. (2012) Weaning predictors do not predict extubation failure in simple-to-wean patients. J Crit Care 27: 221-e1.
  5. Soummer A, Perbet S, Brisson H, Arbelot C, Constantin JM, et al. (2012) Ultrasound assessment of lung aeration loss during a successful weaning trial predicts postextubation distress. Crit Care Med 40: 2064-2072.
  6. Osman AM, Hashim RM (2017) Diaphragmatic and lung ultrasound application as new predictive indices for the weaning process in ICU patients. Egyptian J Radiol Nuc Med 48: 61-66.
  7. Zambon M, Greco M, Bocchino S, Cabrini L, Beccaria PF, et al. (2017) Assessment of diaphragmatic dysfunction in the critically ill patient with ultrasound: A systematic review. Intensive Care Med 43: 29-38.
  8. Palkar A, Narasimhan M, Greenberg H, Singh K, Koenig S, et al. (2018) Diaphragm excursion-time index: A new parameter using ultrasonography to predict extubation outcome. Chest 153: 1213-1220.
  9. Esteban A, Alia I, Gordo F, Fernandez R, Solsona JF, et al. (1997) Extubation outcome after spontaneous breathing trials with T-tube or pressure support ventilation. Am J Respir Crit Care Med 156: 459-465.
  10. Esteban A, AlÍa I, Tobin MJ, Gil A, Gordo F, et al. (1999) Effect of spontaneous breathing trial duration on outcome of attempts to discontinue mechanical ventilation. Am J Resp Crit Care Med 159: 512-518.
  11. Gerscovich EO, Cronan M, McGahan JP, Jain K, Jones CD, et al. (2001) Ultrasonographic evaluation of diaphragmatic motion. J Ultrasound Med 20: 597-604.
  12. Boussuges A, Gole Y, Blanc P (2009) Diaphragmatic motion studied by m-mode ultrasonography: Methods, reproducibility, and normal values. Chest 2009; 135: 391-400.
  13. Ueki J, De Bruin PF, Pride NB (1995) In vivo assessment of diaphragm contraction by ultrasound in normal subjects. Thorax 50: 1157-1161.
  14. Vivier E, Dessap AM, Dimassi S, Vargas F, Lyazidi A, et al. (2012) Diaphragm ultrasonography to estimate the work of breathing during non-invasive ventilation. Intensive Care Med 38: 796-803.
  15. Soummer A, Perbet S, Brisson H, Arbelot C, Constantin JM, et al. (2012) Ultrasound assessment of lung aeration loss during a successful weaning trial predicts postextubation distress. Crit Care Med 40: 2064-2072.
  16. Ferrari G, De Filippi G, Elia F, Panero F, Volpicelli G, et al. (2014) Diaphragm ultrasound as a new index of discontinuation from mechanical ventilation. Critical Ultrasound Journal 6: 8.
  17. DiNino E, Gartman EJ, Sethi JM, McCool FD (2014) Diaphragm ultrasound as a predictor of successful extubation from mechanical ventilation. Thorax 69: 431-435.
  18. Dubé BP, Dres M, Mayaux J, Demiri S, Similowski T, et al. (2017) Ultrasound evaluation of diaphragm function in mechanically ventilated patients: comparison to phrenic stimulation and prognostic implications. Thorax 72: 811-818.
  19. Blumhof S, Wheeler D, Thomas K, McCool FD, Mora J (2016) Change in diaphragmatic thickness during the respiratory cycle predicts extubation success at various levels of pressure support ventilation. Lung 194: 519-525.
  20. Esteban A, Frutos F, Tobin MJ, Alía I, Solsona JF, et al. (1995) A comparison of four methods of weaning patients from mechanical ventilation. New Eng J Med 332: 345-350.
  21. Saeed AM, El Assal GI, Ali TM, Hendawy MM (2016) Role of ultrasound in assessment of diaphragmatic function in chronic obstructive pulmonary disease patients during weaning from mechanical ventilation. Egyptian J Bronchol 10: 167-172.
  22. Baess AI, Abdallah TH, Emara DM, Hassan M (2016) Diaphragmatic ultrasound as a predictor of successful extubation from mechanical ventilation: Thickness, displacement, or both? Egyptian J Bronchol 10: 162-166.
  23. Nemer SN, Barbas CS (2011) Predictive parameters for weaning from mechanical ventilation. J Bras Pneumol 37: 669-679.
  24. Farghaly S, Hasan AA (2017) Diaphragm ultrasound as a new method to predict extubation outcome in mechanically ventilated patients. Aust Crit Care 30: 37-43.
  25. Pirompanich P, Romsaiyut S (2018) Use of diaphragm thickening fraction combined with rapid shallow breathing index for predicting success of weaning from mechanical ventilator in medical patients. J Intensive Care 6: 6.
  26. Mayo P, Volpicelli G, Lerolle N, Schreiber A, Doelken P, et al. (2016) Ultrasonography evaluation during the weaning process: The heart, the diaphragm, the pleura and the lung. Intensive Care Med 42: 1107-1117.
Citation: Fahmy H, Saied M, Sayed I, Kinawy S (2019) Value of Integrated Lung and Diaphragm Ultrasonography in Predicting Extubation Outcomes from Mechanical Ventilation in Patients with Critical Illness. J Anesth Clin Res 10: 923.

Copyright: © 2019 Fahmy H, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Top