Pediatrics & Therapeutics

Pediatrics & Therapeutics
Open Access

ISSN: 2161-0665

+44 1478 350008

A new horizon for pediatric aerosolized medication delivery to infants via high flow nasal cannula and vibrating mesh nebulization


Joint Event on International Conference on Pediatric Pharmacology and Therapeutics & 12th International Conference on Pediatric, Perinatal and Diagnostic Pathology

July 13-14, 2018 | Toronto, Canada

Sherwin Morgan

University of Chicago Medicine, USA

Keynote: Pediatr Ther

Abstract :

Introduction: The global gold standard for delivering aerosolized medication to infants in respiratory distress has been via the Small Volume Jet Nebulizer (SVJN) with a face mask. The medication most commonly used is albuterol 0.083%. During the procedure, a parent must hold the mask on the babyface, which can make the child combative. Therefore, the standard oxygen treatment is moving from face mask to High Flow Nasal cannula (HFNC) in conjunction with aerosolized beta-agonist treatments. A recent study of aerosol drug distribution using a face mask with TC99 label albuterol demonstrated that < less than 1% of the aerosol drug reached the lung and deposition was even less when the infant was crying or upset. Medication delivery is decreased even more when the patient has a nasal cannula in their nose and a pacifier in their mouth. Children are mostly nasal breathers. In vitro pediatric lung model studies with the combination of HFNC&ANB, estimated aerosol deposition at 18 to 26%, although efficacy is low, it is enough to exert a clinical effect when the treatment process was changed to delivery via HFNC and the vibrating mesh nebulizer (Aerogen�® Solo Nebulizer), there was improvement with patient and parent comfort levels. Most children were calm and able to sleep throughout the treatment, keep the pacifiers in and some were able to breastfeed during treatment. The clinical indicator that there was better aerosol medication deposition was that many kids experienced an increased heart rate of 10 to 15% from baseline, although they were not being touched or stimulated. Bedside clinician could see medication aerosol exhalation around the pacifiers. Conclusion: This development has revolutionized aerosolized inhaled medication delivery with the ultra-sonic vibrating mesh nebulizer for infants in respiratory distress. More study is needed in this area.

Biography :

Sherwin Morgan completed his respiratory care training from Malcolm X College of Respiratory Care in Chicago, IL. He is an advanced respiratory care practitioner with the National Board for Respiratory Care in the United States. He is Clinical Practice and Development /Educator/Research Coordinator for the Department of Respiratory Care Services, Section of Pulmonary and Critical Care Medicine at the University of Chicago Medicine. He has published more than 25 peer review papers in multiple medical journals. He has designed, engineered, and collaborated with a number of research studies with the pulmonary medicine department.

E-mail: sherwin.morgan@uchospitals.edu

Top